{"id":403,"date":"2024-09-10T14:59:26","date_gmt":"2024-09-10T14:59:26","guid":{"rendered":"http:\/\/www.bluespark.co.kr\/?post_type=product&#038;p=403"},"modified":"2024-09-16T11:20:02","modified_gmt":"2024-09-16T11:20:02","slug":"%ec%ba%90%eb%b9%84%eb%84%b7-%ec%bf%a8%eb%9f%ac","status":"publish","type":"product","link":"https:\/\/www.bluespark.co.kr\/en\/product\/%ec%ba%90%eb%b9%84%eb%84%b7-%ec%bf%a8%eb%9f%ac\/","title":{"rendered":"Cabinet coolers"},"content":{"rendered":"<h1>cabinet cooler<br \/>\nUsed to cool down the heat inside a case such as a switchboard, etc.<\/h1>\n<div data-id=\"571053c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<h2>Two classifications based on airtightness<\/h2>\n<table width=\"725\">\n<tbody>\n<tr>\n<td width=\"277\"><\/td>\n<td width=\"201\">\n<p data-id=\"081df07\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><strong>NEMA 12 (IP52)<\/strong><\/p>\n<\/td>\n<td width=\"247\">\n<p data-id=\"ea99ae4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><strong>NEMA 4\/4x (IP56)<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p data-id=\"ae2aeac\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Material<\/p>\n<\/td>\n<td>\n<p data-id=\"f84d99f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Stainless Steel (Type 303)<\/p>\n<\/td>\n<td>\n<p data-id=\"f4d96c4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Stainless Steel (Type 303)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p data-id=\"8087433\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Rating<\/p>\n<\/td>\n<td>\n<p data-id=\"5b4dcb5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Dust and Dirt<\/p>\n<\/td>\n<td>\n<p data-id=\"ee098a7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Splash<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p data-id=\"849064f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Capacity BTU\/Hr<\/p>\n<\/td>\n<td>\n<p data-id=\"2fa4b2c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">550 up to 5600<\/p>\n<\/td>\n<td>\n<p data-id=\"92f923d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">550 up to 5600<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p data-id=\"3bdd9df\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Noise level<\/p>\n<\/td>\n<td>\n<p data-id=\"8f0e55f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Low<\/p>\n<\/td>\n<td>\n<p data-id=\"45ac8b4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">Low<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Select a model based on compressed air consumption<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\"><strong>Specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"110\"><strong>Model No.<\/strong><\/td>\n<td width=\"134\"><strong>Capacity Btu\/hr.<\/strong><\/td>\n<td width=\"145\"><strong>Capacity Watt\/hr.<\/strong><\/td>\n<td width=\"137\"><strong>Air Consumption SCFM @ 80 PSI<\/strong><\/td>\n<td width=\"132\"><strong>Air Consumption SLPM @ 5.5 Bar<\/strong><\/td>\n<td width=\"69\"><strong>Sound Level<\/strong><\/td>\n<\/tr>\n<tr>\n<td>CC1208-1<\/td>\n<td>550<\/td>\n<td>161<\/td>\n<td>8<\/td>\n<td>226<\/td>\n<td>67*<\/td>\n<\/tr>\n<tr>\n<td>CC1215-1<\/td>\n<td>1,100<\/td>\n<td>322<\/td>\n<td>15<\/td>\n<td>425<\/td>\n<td>73*<\/td>\n<\/tr>\n<tr>\n<td>CC1225-1<\/td>\n<td>1,800<\/td>\n<td>528<\/td>\n<td>25<\/td>\n<td>708<\/td>\n<td>74*<\/td>\n<\/tr>\n<tr>\n<td>CC1230-1<\/td>\n<td>2,060<\/td>\n<td>603<\/td>\n<td>30<\/td>\n<td>849<\/td>\n<td>74*<\/td>\n<\/tr>\n<tr>\n<td>CC1240-1<\/td>\n<td>2,800<\/td>\n<td>821<\/td>\n<td>40<\/td>\n<td>1,132<\/td>\n<td>79*<\/td>\n<\/tr>\n<tr>\n<td>CC1250-1<\/td>\n<td>3,400<\/td>\n<td>996<\/td>\n<td>50<\/td>\n<td>1,415<\/td>\n<td>74*<\/td>\n<\/tr>\n<tr>\n<td>CC1260-1<\/td>\n<td>4,000<\/td>\n<td>1,171<\/td>\n<td>60<\/td>\n<td>1,698<\/td>\n<td>76*<\/td>\n<\/tr>\n<tr>\n<td>CC1270-1<\/td>\n<td>4,800<\/td>\n<td>1,406<\/td>\n<td>70<\/td>\n<td>1,981<\/td>\n<td>76*<\/td>\n<\/tr>\n<tr>\n<td>CC1280-1<\/td>\n<td>5,600<\/td>\n<td>1,640<\/td>\n<td>80<\/td>\n<td>2,264<\/td>\n<td>77*<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<h1>Cooling unit required to cool hot air with compressed air in switchboards<\/h1>\n<div data-id=\"571053c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<h2><\/h2>\n<\/div>","protected":false},"featured_media":579,"template":"","meta":{"_acf_changed":false},"product_cat":[49],"product_tag":[],"class_list":{"0":"post-403","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-stremtek","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/www.bluespark.co.kr\/en\/wp-json\/wp\/v2\/product\/403","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bluespark.co.kr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.bluespark.co.kr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bluespark.co.kr\/en\/wp-json\/wp\/v2\/media\/579"}],"wp:attachment":[{"href":"https:\/\/www.bluespark.co.kr\/en\/wp-json\/wp\/v2\/media?parent=403"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.bluespark.co.kr\/en\/wp-json\/wp\/v2\/product_cat?post=403"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.bluespark.co.kr\/en\/wp-json\/wp\/v2\/product_tag?post=403"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}